NTV 2001/111

Modelisation of monozone natural ventilation with ducts

Résumé et principaux résultats

Communication à la 22ème Conférence de l'AIVC, 11-14 September 2001, Bath
Abstract : European project pr EN13465 from CEN TC 156/WG2/AH4 gives a monozone model for airflows calculations in dwellings. In order to apply it to natural ventilation systems with adjacent ducts used in dwellings in France, we need to address several issues. First, in adjacent ducts, airflows at each level depends on pressions in the different dwellings. We have to solve by iteration the balanced equation proposed in AH4. Then, cowls and roof outlet performances as well as the wind-pressure coefficient on the roof must be known. Finally, for dimensioning purpose, airflows must be calculated including the air transfer between rooms. As the dwelling is considered in monozone, taking it directly into account is impossible and the study considered it as an additionnal pressure drop.

Thème

Ventilation et qualité de l'air

Mots-clés

Modélisation, Ventilation

Auteurs

BERNARD Anne-Marie, VIALLE Pierre-Jean

Marie-Claude LEMAIRE (ADEME), Olivia NOEL (GDF), Pierre BARLES (PBC)

Information aux visiteurs

Nous venons de mettre en ligne la nouvelle version du site du CETIAT.

Dans le cadre de cette évolution, certaines données et contenus sont encore en cours de migration. Il est donc possible que certaines informations soient temporairement incomplètes ou que certaines fonctionnalités nécessitent encore quelques ajustements.

Nos équipes restent pleinement mobilisées pour finaliser cette transition et enrichir progressivement les contenus du site.

Nous vous remercions pour votre compréhension et nous excusons pour la gêne occasionnée.