Our means: On-site intervention teams: emission measurements |
|
|
 |
ACCREDITATION
N°1-0021
PROGRAM 97 |
|
|
Equipment of the laboratory vehicle
- Gas and particle compounds sampling chains: dust, metals,
mercury, HCI, HF, NH3, SOx , moisture, specific
organic compounds, dioxins, furans, PAHs, etc.
- Analysers for continuous measurement of gas concentrations: O2,
CO2, CO, NOx, N2O, SO2,
H2O, total VOC, non-methanic VOC,
CH4.
- Data acquisition system
- Gas flows characterisation system: Pitot tubes, anemometers, search gas, suction pyrometers, etc.
|
List of the COFRAC accredited tests - Programme 97 “Emission measurements”
| COFRAC codes |
NATURE OF THE TEST |
REFERENCE STANDARDS |
| ME10 |
Dust sampling in a gas stream (general case) |
NF X 44-052
NF EN 13284-1 |
| ME20 |
Determination of a coefficient relating to the organic compounds in gas phaseFlame ionization method |
NF EN 13211 |
| ME31 |
Determination of mercury concentration (Hg). Manual method - sampling part |
X 43-308 |
| ME41 |
HCI dosage manual method - part 1: gas sampling |
NF EN 1911-1 |
| ME51 |
Determination of the massic concentration of polychlorinated dibenzo-p-dioxins (PCDD) and polychlorinated dibenzofurans (PCDF) - part 1: sampling |
NF EN 1948-1 |
| ME61 |
Polycyclic aromatic hydrocarbons and tars emission sampling and measurement - sampling part |
XP X 43-329 |
| ME71 |
Fluorhydric acid (HF) emission determination. Manual method - sampling part |
XP X 43-304 |
| ME90 |
Continuous gas sampling by extractive methods. Ambient air - nitrous oxide dosage by chemiluminescence |
XP X 43-300
NF X 43-018 |
| ME100 |
Continuous gas sampling by extractive methods. Carbon monoxide dosage in the outside ambient air by absorption of infrared radiation |
XP X 43-300
NF X 43-012 |
| ME111 |
Determination of the mass concentration of sulphur dioxide - ion chromatography method |
ISO 11632 |
| ME120 |
Method of oxygen analysis based on the paramagnetic properties of this gas |
Fd X 20-377 |
| ME130 |
Measurement of velocity and volume flow rate of gas flows in the mains |
ISO 10780 |
| ME141 |
Determination of the total emission of heavy metals and other specific composites - sampling part |
XP X 43-051 |
|
Laboratory vehicle

CETIAT has one laboratory vehicle available for on-site interventions
in order to determine the atmospheric emissions of the installations
|
|
|